ELECTROCHEMICAL DETERMINATION OF AMLODIPINE BESILATE AND BENAZEPRIL HYDROCHLORIDE IN THEIR BINARY MIXTURE USING PVC AND COATED GRAPHITE SENSORS

Authors

  • Khalid A.M. Attia
  • Mohammed W.I. Nassar
  • Ahmed El-Olemy
  • Sherif Ramzy Al-Azhar university

Abstract

Objective—Design and prepare two ion selective electrodes, Amlodipine–PVC sensor and Benazepril–coated graphite sensor for determination of amlodipine besilate and benazepril hydrochloride in their binary mixture. Methods— The sensors design is based on the ion pair of amlodipine besilate or benazepril hydrochloride with sodium tetraphenylborate using dioctylphthalate as a plasticizer. Results— Under the optimum conditions, the proposed sensors shows the slopes of 28.400 and 58.500 mV per concentration decade  in the concentration range of 10-5 – 10-2 for amlodipine besilate and benazepril hydrochloride, respectively . The sensors exhibit a very good selectivity for the studied drugs with respect to a large number of interfering ions. The sensor enables determining the studied drugs in their binary mixtures with good percent recovery of each drug which indicates the higher selectivity of the prepared sensors. Conclusion—The sensors were successfully used for potentiometric determination of amlodipine besilate and benazepril hydrochloride in pure solutions and in their combined dosage form.

References

References

Sweetman S. Martindale: the complete drug reference. 36th ed. London: The Pharmaceutical Press; 2009.

Kavathia A, Misra M. Development and validation of RP-HPLC and UV-spectrophotometric methods for rapid simultaneous estimation of amlodipine and benazepril in pure and fixed dose combination. Arabian J Chem. 2017; 10:S3021-8.

Sarat M, Krishna PM, Rambabu C. Development and validation of RPHPLC method for simultaneous estimation of amlodipine besylate and benazepril HCl in tablet dosage form. Int J Curr Pharm Res. 2012;4(3):80-4.

Ashour S, Sakur AA, Kudemati M. A validated stability-indicating liquid chromatographic method for the simultaneous determination of Amlodipine and benazepril in capsules dosage form. Can chem trans. 2014;2(4):418-33.

Kasawar GB, Farooqui M. Stability-indicating RP-UPLC method for the simultaneous determination of potential degradation and process impurities of amlodipine basylate and benazepril HCl in pharmaceutical dosage form. Orbital: Electron J Chem. 2014;6(3):130-41.

Meyyanathan SN, Suresh B. HPTLC method for the simultaneous determination of amlodipine and benazepril in their formulations. J chromatogr sci. 2005; 43(2):73-5.

Rezk MR, Badr KA. Development, optimization and validation of a highly sensitive UPLC–ESI-MS/MS method for simultaneous quantification of amlodipine, benazeprile and benazeprilat in human plasma: Application to a bioequivalence study. J Pharm Biomed Anal. 2014; 98:1-8.

Hemdan A. Development and validation of different methods manipulating zero order and first order spectra for determination of the partially overlapped mixture benazepril and amlodipine: A comparative study. Spectrochim Acta Part A. 2016; 164:52-60.

Farouk M, Elaziz OA, Tawakkol SM, Hemdan A, Shehata MA. Comparative study between univariate spectrophotometry and multivariate calibration as analytical tools for quantitation of Benazepril alone and in combination with Amlodipine. Spectrochim Acta Part A. 2014; 123:473-81.

Kavathia A, Suchak K, MISRA M. Application of absorption correction method and first order derivative spectrophotometry for simultaneous determination of anti-hypertensive combination (amlodipine and benazepril). International J Pharm Pharm Sci.2013; 5(3):371-5.

Joshi HV, Patel JK. New Spectrophotometric Methods for Simultaneous Determination of Amlodipine besylate and Benazepril in Tablet Dosage Forms. Int J Adv Pharm Biol Chem 2012; 1(1): 35-8.

United States Pharmacopoeia 30 National formulary 24, United State Pharmacopoeia Convention, 2007.

Thomas JDR. Ion-selective electrode reviews. Amsterdam: Elsevier; 2013.

Attia, KAM, El-Abasawi, NM, El-Olemy, A, Abdelazim AH. Comparative study of different electrochemical sensors for determination of phenazopyridine hydrochloride in the presence of its computationally selected degradation product, Anal. Chem. Letters, 2017, 7(6): 765-778.

Buck RP, Lindner E. Recommendations for nomenclature of ion-selective electrodes. Pure App Chem. 1994; 66(12): 2527–36.

Bakker E, Pretsch E, Bühlmann P. Selectivity of potentiometric ion sensors. Anal. Chem. 2000; 72(6):1127-33.

Q.B. I

Downloads

Published

2018-06-06

How to Cite

Attia, K. A., Nassar, M. W., El-Olemy, A., & Ramzy, S. (2018). ELECTROCHEMICAL DETERMINATION OF AMLODIPINE BESILATE AND BENAZEPRIL HYDROCHLORIDE IN THEIR BINARY MIXTURE USING PVC AND COATED GRAPHITE SENSORS. Innoriginal: International Journal of Sciences, 28–32. Retrieved from https://innoriginal.com/index.php/iijs/article/view/171